Mechanical Insulation Appraisal · Preliminary Report

Anheuser-Busch Brewery - St Louis MO - Bldg 26

Engineered findings from a NAIMA 3E Plus walk-down assessment. 8 items inventoried across 1 systems · estimated $1,927/yr in recoverable operating cost.

Executive Summary

Overview of identified insulation upgrade opportunities and projected annual savings. This is a Preliminary Report. Please see the 'Line Item Detail' Page for detailed information about each item assessed along with Infrared Imaging. Your EEQA representative will now solicit bids from our Qualified Contractors. Please allow 4-6 weeks for the bidding to complete. Your EEQA representative will then submit to you a Final Report upon it's completion. All completed upgrades will have a Quality Control visit to ensure the Mechanical Insulation was installed in accordance with specifications.

Estimated Annual Savings
$1,927/yr
Energy cost reduction from upgrades
Current Operating Cost
$2,133/yr
Inventoried surface annual cost
Upgraded Operating Cost
$206/yr
After insulation improvements
Cost Reduction
90.3%
Operating cost decrease
Heat Flow Reduction
296,823kBtu/yr
296.8 MMBtu/yr saved
CO₂ Reduction
19.61MT/yr
Metric tons per year
NOₓ Reduction
85.3lbs/yr
Pounds per year
Items Assessed
8items
Across 1 systems
Annual Operating Cost Comparison
Current (As-Found)
$2,133
per year
After Upgrade
$206
per year

Upgrading the insulation on the 8 identified items would result in estimated annual energy cost savings of $1,927/yr, a reduction in heat flow of 296,823 kBtu/yr, a reduction in CO₂ emissions of 19.61 MT/yr, and a reduction in NOₓ emissions of 85.3 lbs/yr. All calculations were performed using the NAIMA 3E Plus (version 5.1) computer program.

Savings Analysis

Energy cost savings by system area, ranked by annual impact.

Annual Energy Cost Savings by System
5-Year Projected Savings
5-Year Energy Savings
$9,637
Cumulative cost avoidance
5-Year Heat Flow Saved
1,484MMBtu
Cumulative thermal savings
5-Year CO₂ Avoided
98.1MT
Equivalent to ~4 cars off the road/yr
Environmental Impact

Emissions reductions achieved through insulation upgrades.

CO₂ Reduction
19.61MT/yr
Metric tons carbon dioxide
NOₓ Reduction
85.3lbs/yr
Pounds nitrogen oxides
Equivalent Cars Removed
~4/yr
Based on avg 4.6 MT CO₂/car/yr
Heat Flow Saved
296.8MMBtu/yr
Thermal energy conserved
CO₂ Reduction by System
System Breakdown

Summary of each system/equipment group.

SystemItemsCurrent $/yrUpgraded $/yrSavings $/yrHeat kBtu/yrCO₂ MT/yrNOₓ lbs/yr
Line-Item Detail

Complete per-item inventory with specifications and savings. Click the Item Description to view Thermal Images.

#DescriptionPipeQtyTemp °FInv. Ins.Upg. Ins.Inv ThkUpg ThkCurrent $/yrUpgraded $/yrSavings $/yrHeat kBtu/yrCO₂ MT/yr
Thermal Imaging

Infrared and visible-light photo pairs for each assessed equipment item.

STL 167

Valve & Bonnet · Level 2 · Ref: 145341
Infrared
IR: Ref 145341 - IR
Ref 145341 - IR
Visible
VIS: Ref 145341 - VIS
Ref 145341 - VIS

STL 167

Valve & Bonnet · Level 2 · Ref: 145428
Infrared
IR: Ref 145428 - IR
Ref 145428 - IR
Visible
VIS: Ref 145428 - VIS
Ref 145428 - VIS
Parameters & Methodology

Project-specific inputs and calculation methodology.

Project Parameters
Boiler Efficiency80%
Hours of Operation8,300 hrs/yr
Ambient Temperature75 °F
Wind Speed0 mph
Fuel TypeNatural Gas
Fuel Cost$5.33/Mcf

Calculation Engine

All calculations performed using NAIMA 3E Plus (v5.1), based on ASTM C680 methodology.

Inventoried Condition

Each item assessed in as-found condition. Bare surfaces have no insulation present.

Upgraded Specification

Recommended upgrades include fiberglass, cellular foam, elastomeric, and ceramic fibre materials.

Emissions Methodology

CO₂ and NOₓ calculated using EPA fuel-specific emission factors applied to energy saved.